TransMedics
Search
Home   |   US Site   |   Contact Us   |   Site Map
Publications

Contact Information

Members of the press seeking additional information about TransMedics are invited to contact:


Download Adobe Acrobat Reader

Published Manuscripts

Lung

  • Perfusion
    Utilization of the organ care system for bilateral lung transplantation: preliminary results of a comparative study. 2016.
    Zeriouha M, Sabashnikov A, Mohite PN, et al.

  • Medical Science Monitor Basic Research
    Utilization of the Organ Care System – A Game-Changer in Combating Donor Organ Shortage. 2015.
    Popov A-F, Sáez DG, Sabashnikov A, et al.

  • European Journal of Cardio-Thoracic Surgery
    Long-term results after lung transplantation using organs from circulatory death donors: a propensity score-matched analysis. 2015.
    Sabashnikov A, Patil NP, Popov A-F, et al.

  • Canadian Respiratory Journal
    Lung transplantation from donors after circulatory death using portable ex vivo lung perfusion. 2015.
    Bozos S, Vasanthan V, Luc J, et al.

  • Perfusion
    Utilization of the Organ Care System Lung for the Assessment of lungs from a donor after cardiac death (DCD) before bilateral transplantation. 2015.
    PN Mohite, F De Robertis. AR Simon et. al.

  • American Journal of Transplantation
    Combined Liver and Lung Transplantation With Extended Normothermic Lung Preservation in a Patient With End-Stage Emphysema Complicated by Drug-Induced Acute Liver Failure. 2014.
    Ceulemans LJ, Monbaliu D, Verslype C, et al.

  • The Lancet
    Normothermic perfusion of donor lungs for preservation and assessment with the Organ Care System Lung before bilateral transplantation: a pilot study of 12 patients. 2012.
    Warnecke G, Maradiellos J, Haverich A et. al.

Heart

  • The Lancet
    Ex-vivo perfusion of donor hearts for human heart transplantation (PROCEED II): a prospective, open-label, multicentre, randomised non-inferiority trial. 2015.
    Ardehali A, Esmailian F, Deng M, et al.

  • The Lancet
    Adult heart transplantation with distant procurement and ex-vivo preservation of donor hearts after circulatory death: a case series. 2015.
    Dhital KK, Iyer A, Connellan M, et al.

  • The American Journal of Transplantation
    Normothermic Ex Vivo Perfusion Provides Superior Organ Preservation and Enables Viability Assessment of Hearts From DCD Donors. 2015.
    Iyer, K. K. Dhital and P. S. MacDonald et. al.

  • Heart, Lung and Circulation
    Successful Heart Transplant after Ten Hours Out-of-body Time using the TransMedics Organ Care System. 2015.
    Stamp NL, Shah A, Vincent V, et al.

  • Transplant International
    Normothermic donor heart perfusion: current clinical experience and the future. 2015.
    Simon Messer, Abbas Ardehali and Steven Tsui

  • Annals of Thoracic Surgery
    Evaluation of the Organ Care System in Heart Transplantation With an Adverse Donor/Recipient Profile. 2014.
    Diana Garcia Saez, Nicholas R. Banner, Andre R Simon et. al.

  • Applied Cardiopulmonary Pathophysiology
    Organ Preservation with the Organ Care System. 2011.
    Yeter R, Hübler M, Knosalla, C et al.

  • Journal of Thoracic and Cardiovascular Surgery
    Continuous Perfusion of Donor Hearts in the Beating State Extends Preservation Time and Improves Recovery of Function. 1998.
    Hassanein WH, Zellos L, Khuri S et. al.

Kidney

  • Transplant Proceedings
    A Paired Study Comparing the Efficacy of Renal Preservation by Normothermic Autologous Blood Perfusion and Hypothermic Pulsatile Perfusion. 2002.
    Metcalfe M, Waller J, Nicholson M et. al.

Economics

  • Transplantation
    Life-Years Gained by Reducing Donor Heart Ischemic Times. 2009.
    Goldsmith K, Demiris N, Tsui, S et. al.

Published Abstracts

Heart

  • Moradiellos F, Córdoba M, Merlo P, et al. First Lung Transplants Using Controlled and Uncontrolled DCD Lungs Evaluated With OCS-Lung Portable Exvivo Perfusion System. J Heart Lung Transplant 2014; Vol 32, No 4S, Page S96
  • Deng M, Soltesz E, Naka Y et al. Is Lactate Level During Warm Perfusion a Predictor for Post Transplant Outcomes? Poster Session 1: Heart Donor Management Organ Allocation at The International Society of Heart & Lung Transplantation (ISHLT). Montréal, Canada. The Journal of Heart and Lung Transplantation. April 2013. Vol. 32, Issue 4. Supplement. Pgs. S516- 57.
  • Deng M, Soltesz E, Naka Y et al. Ex-Vivo Perfusion of Human Donor Hearts Reduces Cold Ischemia Time. Poster Session 1: Heart Donor Management Organ Allocation at The International Society of Heart & Lung Transplantation (ISHLT). Montréal, Canada. The Journal of Heart and Lung Transplantation. April 2013. Vol. 32, Issue 4. Supplement. Pg. S156.
  • Esmailian F, Kobashigawa J, Naka Y et al. The PROCEED II International Heart Transplant Trial with the Organ Care System Technology (OCS). Presentation at the International Society of Heart & Lung Transplantation (ISHLT). Montréal Canada. The Journal of Hearth and Lung Transplantation. April 2013; Vol. 32: Number 4S. Pgs. S95 – S96.
  • Ghodsizad A. Ex vivo coronary angiography of a donor heart in the Organ Care System. The Heart Surgery Forum. June 2012. Vol. 15, Issue 2. Pg. 161.
  • Goldsmith, K, Demiris, N, Gooi, J, et al. Life-Years Gained by Reducing Donor Heart Ischemic Times. Transplantation. January 2009; Vol. 87: Number 2. Pgs. 243 – 48.
  • Hamed A, Tsui, S, Huberm J, et al. Serum lactate is a highly sensitive and specific predictor of post-cardiac transplant outcomes using The Organ Care System. Paper presented at The International Society of Heart & Lung Transplantation (ISHLT). , Palais des Congres, Paris, France. The Journal of Heart and Lung Transplantation. February 2009. Vol. 28, pg. S71.
  • Hassanein A.H, Elbetanony A, Abdelaziem A, et al. The Organ Care System (OCS) Enables Ex-Vivo Assessment of Donor Heart Coronary Perfusion Using Contrast Echocardiography. The Journal of Heart and Lung Transplantation. February 2009. Vol. 28. Pg. S150
  • Hassanein, W.H, Zellos, L, Tyrrell, T, et al. (1997). A novel technique for prolonged endothelial & myocardial preservation of the donor heart. Paper presented at Cardiac Allograft Vasculopathy symposium, The Second International Syposim on cardiac allograph vasculopothy. Hamilton, Bermuda.
  • Hassanein W.H, Zellos L, Tyrrell T, et al. (November 1997). A novel approach for 12-hour donor heart preservation. Paper presented at the 70th meeting of The American Heart Association. Orlando, Florida. AHA – look for the. Supplement.
  • Hassanein W.H. Continuous perfusion of donor hearts in the beating state extends preservation time and improves recovery of function. Journal Thoracic Cardiovascular Surgery. November 1998. Issue 116, Vol 5. Pgs. 821 - 30.
  • Hassanein W.H. (April, 1998). Presentation. Resuscitation of donor hearts for transplantation. Paper presented at the 22nd Scientific Session Annual Meeting of the Association of VA Surgeons. Baltimore, MD.
  • Iyer A, Gao, L, Doyle, A, et al. Hearts from donations after circulatory death (DCD) donors: assessment in a porcine transplant model utilizing TransMedics Organ Care System for Organ Perfusion Preservation. Presentation at Mini Oral Session 5: Basic Science. The International Society of Heart & Lung Transplantation (ISHLT). Montréal, Canada. The Journal of Heart and Lung Transplantation. April 2013. Vol. 32, Number 4S. Pgs. S68 – S69.
  • McCurry K, Jeevanandam, T, Mihaljevic, G et al. Prospective multi-center safety and effectiveness evaluation of the Organ Care System Device for Cardiac Use (PROCEED). Paper presented at The International Society of Heart & Lung Transplantation (ISHLT). Boston, MA. The Journal of Heart and Lung Transplantation. February 2008. Vol. 27, Issue 2, Supplement, pgs. S167 – 68.
  • Schnitzler, M.A, Buchanan P.M, Swindle, J, et al. The cost-effectiveness of increasing the supply of hearts for transplant. Paper presented at The International Society of Heart & Lung Transplantation (ISHLT). Boston, MA. February 2007. The Journal of Heart and Lung Transplantation. Vol. 26, Issue 2. Supplement. Pg. S63
  • Schulte-Eistrup, S, Schultz, U, Elbetanony, A, et al. Ex-vivo evaluation of donor hearts in the beating functioning state in the organ care system. The Journal of Heart and Lung Transplantation. February 2007. Vol. 26, Issue 2. Supplement. Pg. S167.
  • Tenderich, S, Tsui, Khayal, et al. Increasing organ availability in heart transplantation with the use of warm blood perfusion for organ preservation. The Journal of Heart and Lung Transplantation. February 2007. Vol. 26. Supplement. Pgs. S167 – 68.
  • Tenderich G, El-Banayosy, A, Rosengard, B, et al. Prospective multi-center European trial to evaluate the safety and performance of the Organ Care System for Heart Transplants (PROTECT). Paper presented at The International Society of Heart & Lung Transplantation (ISHLT). San Diego, CA. The Journal of Heart and Lung Transplantation. February 2007. Vol. 26, Issue, 2, Supplement, pg. S64.
  • Tenderich, G, Tsui, S, El-Banayosy, A, et al. The 1-year follow-up results of the PROTECT Patient Population Using the Organ Care System. Paper presented at The International Society of Heart & Lung Transplantation (ISHLT). Boston, MA. The Journal of Heart and Lung Transplantation. February 2008. Vol. 27, Issue 3. Supplement. Pg. S200.
  • Tsui, S, Dhital, K, Eisenring, C, et al. Ex-vivo assessment of donor hearts with the OCS to detect hidden pathologies. Paper presented at The International Society of Heart & Lung Transplantation (ISHLT). Boston, MA. The Journal of Heart and Lung Transplantation. February 2008. Vol. 27, Issue 2. Supplement. Pg. S200.

Lung

  • Warnecke G, A. Haverich, G. Massard, N. Santelmo, et al. The INSPIRE International Lung Trial with the Organ Care System Technology (OCS™). J Heart Lung Transplant 2012; Vol. 31, Issue 4, Supplement, Pages S115.
  • Avsar M, G. Warnecke, F. Ius, A. Haverich, et al.: Successful 24-Hour Ex-Vivo Maintenance of Swine Lungs Using the Organ Care System (OCS™). J Heart Lung Transplant 2012; Vol. 31, Issue 4, Supplement, Pages S141-S142
  • Redha Souilamas, Jihane Iris Souilamas, Mauricio Saueressig, Raphael Briot: Advanced normothermic ex vivo lung maintenance using the mobile Organ Care System. J Heart Lung Transplant 2011; Vol. 30, Issue 7, Pages 847-848



Secure Access ©2017 TransMedics, Inc.   |   Privacy Policy   |   Legal Notice